Environ Sci Pollut Res Int ; 29(57): 85727-85741, 2022 Dec.
Article in English | MEDLINE | ID: covidwho-1616214

ABSTRACT

The enforcement of the Movement Control Order to curtail the spread of COVID-19 has affected home energy consumption, especially HVAC systems. Occupancy detection and estimation have been recognized as key contributors to improving building energy efficiency. Several solutions have been proposed for the past decade to improve the precision performance of occupancy detection and estimation in the building. Environmental sensing is one of the practical solutions to detect and estimate occupants in the building during uncertain behavior. However, the literature reveals that the performance of environmental sensing is relatively poor due to the poor quality of the training dataset used in the model. This study proposed a smart sensing framework that combined camera-based and environmental sensing approaches using supervised learning to gather standard and robust datasets related to indoor occupancy that can be used for cross-validation of different machine learning algorithms in formal research. The proposed solution is tested in the living room with a prototype system integrated with various sensors using a random forest regressor, although other techniques could be easily integrated within the proposed framework. The primary implication of this study is to predict the room occupation through the use of sensors providing inputs into a model to lower energy consumption. The results indicate that the proposed solution can obtain data, process, and predict occupant presence and number with 99.3% accuracy. Additionally, to demonstrate the impact of occupant number in energy saving, one room with two zones is modeled each zone with air condition with different thermostat controller. The first zone uses IoFClime and the second zone uses modified IoFClime using a design-builder. The simulation is conducted using EnergyPlus software with the random simulation of 10 occupants and local climate data under three scenarios. The Fanger model's thermal comfort analysis shows that up to 50% and 25% energy can be saved under the first and third scenarios.


Subject(s)
Air Pollution, Indoor , COVID-19 , Humans , Air Pollution, Indoor/analysis , Air Conditioning , Climate , Efficiency
SELECTION OF CITATIONS
SEARCH DETAIL